Pharmaceutical X-Ray inspection systems are devices that detect foreign objects (metal, glass, stone, rubber) in tablets, capsules, syringes, and blister packs using dual-energy or single-energy X-ray technology. This article compares 5 leading pharmaceutical X-Ray systems — Mettler Toledo X37, Eagle Pack 400, Anritsu KD74 Series, Loma X5, and Sesotec Raycon D — to help you choose the right solution for your budget, FDA standards, and support capabilities in Vietnam in 2026.
Mettler Toledo X37 — Comprehensive High-End Pharmaceutical X-Ray System

The Mettler Toledo X37, part of the Safeline X-Ray series, integrates dual-energy X-ray technology, detecting metal (iron, steel, aluminum) and non-metal (glass, stone, rubber, hard plastic) foreign objects with sensitivity up to 0.3 mm for iron particles and 0.5 mm for glass. The system fully complies with FDA 21 CFR Part 11, GMP Annex 1, and supports SCADA connectivity via OPC-UA. Suitable for large-scale pharmaceutical plants with high-speed lines (up to 800 products/minute).
The Mettler Toledo X37 is the only model among the 5 systems that comes pre-integrated with SimulTask PRO — a real-time image processing software that distinguishes foreign objects from products based on density. This reduces the false reject rate to below 0.1% at the 0.5 mm threshold. The system includes an optional enclosed conveyor (IP65) for humid or dusty environments, common in liquid production areas (syringes, dropper vials).
According to a survey from Comparison of Mettler Toledo vs Competitors: Which X-Ray Machine to Choose for Food? — the sensitivity specifications of the X37 were confirmed through independent testing at the Ho Chi Minh City Drug Testing Laboratory in 2025.
Eagle Pack 400 — X-Ray Solution for Liquid Pharmaceuticals and Syringes
Related Products

The Eagle Pack 400 (brand Eagle Product Inspection, part of the Mettler Toledo group) is specialized for inspecting liquid pharmaceuticals, glass syringes, and dropper vials. It uses single-energy X-ray technology combined with density analysis algorithms, detecting foreign objects down to 0.4 mm for glass and 0.2 mm for metal. Maximum speed is 600 products/minute, suitable for medium-scale lines.
The Eagle Pack 400 has a compact design (1.2 m length), making it easy to integrate into existing packaging lines. The system complies with FDA 21 CFR Part 11 via Eagle Inspection Vision software, supporting CSV and PDF report export. However, its ability to detect non-metal foreign objects (rubber, hard plastic) is lower than the Mettler Toledo X37 due to using only single-energy X-ray. The reference price is approximately 20-25% lower than the X37.
Anritsu KD74 Series — Japanese Pharmaceutical X-Ray with High Accuracy

The Anritsu KD74 Series (Japan) uses dual-energy X-ray technology with a 0.2 mm pixel pitch sensor, detecting metal foreign objects down to 0.2 mm and glass down to 0.4 mm. The system complies with GMP, HACCP, and FDA Part 11 via the optional Anritsu iVision software. Suitable for Japanese pharmaceutical plants or those requiring Japanese manufacturing standards (JIS).
The strength of the Anritsu KD74 is its ability to analyze foreign objects in high-density products (tablets containing metal powder, hard gel capsules). The system has an optional IP65 enclosed conveyor and integrates an inline checkweigher. However, technical support in Vietnam is limited — only representatives in Hanoi and Ho Chi Minh City through distribution partners, with an average response time of 4-6 business hours.
Loma X5 — UK Pharmaceutical X-Ray System at a Competitive Price

The Loma X5 (Loma Systems, UK) uses single-energy X-ray technology with the X-IQ algorithm, detecting metal foreign objects down to 0.3 mm and glass down to 0.6 mm. Maximum speed is 500 products/minute, suitable for small to medium-scale lines. The system complies with FDA 21 CFR Part 11 via Loma IQ Insight software, supporting Ethernet/IP and Profinet connectivity.
The Loma X5 is priced approximately 30-35% lower than the Mettler Toledo X37, making it a budget option for newly established pharmaceutical plants. The system supports up to 50 product recipes stored in memory, allowing quick changeovers between product lines. However, its detection sensitivity for glass and rubber is lower than the X37 and KD74, and it does not offer an IP65 enclosed conveyor option (only IP54).
Sesotec Raycon D — German Pharmaceutical X-Ray Specializing in Small Foreign Object Detection

The Sesotec Raycon D (Germany) uses dual-energy X-ray technology with a 0.1 mm pixel pitch sensor — the highest resolution among the 5 systems. It detects metal foreign objects down to 0.15 mm and glass down to 0.3 mm. Maximum speed is 700 products/minute. The system complies with FDA 21 CFR Part 11, GMP Annex 1, and CE standards. Suitable for pharmaceutical plants requiring detection of ultra-small foreign objects (below 0.3 mm).
The Sesotec Raycon D has the highest price among the 5 systems (approximately 15-20% higher than the X37). The system comes standard with an IP65 enclosed conveyor, integrated checkweigher, and barcode reader. However, technical support in Vietnam is very limited — no representative office, only remote support via a Singapore partner, with an average response time of 8-12 business hours.
Detailed Comparison Table of 5 Pharmaceutical X-Ray Systems 2026

The comparison table below summarizes 5 main criteria: detection sensitivity (metal and glass), 5-year total cost of ownership (TCO), FDA 21 CFR Part 11 integration capability, technical support in Vietnam, and suitable product range.
| Criteria | Mettler Toledo X37 | Eagle Pack 400 | Anritsu KD74 | Loma X5 | Sesotec Raycon D |
|---|---|---|---|---|---|
| Metal sensitivity (iron) | 0.3 mm | 0.2 mm | 0.2 mm | 0.3 mm | 0.15 mm |
| Glass sensitivity | 0.5 mm | 0.4 mm | 0.4 mm | 0.6 mm | 0.3 mm |
| X-ray technology | Dual-energy | Single-energy | Dual-energy | Single-energy | Dual-energy |
| Maximum speed (products/min) | 800 | 600 | 700 | 500 | 700 |
| FDA 21 CFR Part 11 | Yes (standard) | Yes (optional) | Yes (optional) | Yes (optional) | Yes (standard) |
| Conveyor IP rating | IP65 (optional) | IP54 | IP65 (optional) | IP54 | IP65 (standard) |
| 5-year TCO (USD) | ~85,000-95,000 | ~65,000-75,000 | ~70,000-80,000 | ~55,000-65,000 | ~100,000-115,000 |
| Technical support in Vietnam | Direct (HCMC/Hanoi) | Via partner | Via partner | Via partner | Remote (Singapore) |
| Response time | 2-4 hours | 4-6 hours | 4-6 hours | 6-8 hours | 8-12 hours |
Note: 5-year TCO includes equipment, installation, first-year maintenance, and annual maintenance fees. Reference prices for the Vietnamese market as of March 2026.
See also Mettler Toledo X37 2026 Price List: Genuine X-Ray Machine in Vietnam for details on support packages in Vietnam.
Selection by Use Case — Which X-Ray System is Suitable?
Each pharmaceutical use case requires a different X-Ray configuration. Below are 3 common scenarios and optimal system recommendations based on sensitivity, cost, and support criteria.
Use Case 1: Large-scale pharmaceutical plant with diverse products (tablets + syringes + dropper vials)
Recommendation: Mettler Toledo X37 — High sensitivity (0.3 mm metal, 0.5 mm glass), dual-energy technology detects non-metal foreign objects. Standard FDA Part 11 compliance, direct technical support in HCMC and Hanoi. 5-year TCO of ~85,000-95,000 USD is reasonable for a 3-shift production plant.
Use Case 2: Medium-scale pharmaceutical plant with limited budget (tablets, capsules)
Recommendation: Loma X5 — Lowest price (~55,000-65,000 USD TCO 5 years), meets FDA Part 11 requirements. Suitable for basic foreign object detection needs. However, sensitivity for glass and rubber is lower, so it is not recommended for liquid or syringe products.
Use Case 3: Pharmaceutical plant requiring ultra-small foreign object detection (below 0.3 mm)
Recommendation: Sesotec Raycon D — Highest sensitivity (0.15 mm metal, 0.3 mm glass), standard IP65 enclosed conveyor. Suitable for high-value products such as injectable drugs, vaccines, and biologics. However, technical support in Vietnam is limited, requiring proactive maintenance planning.
Frequently Asked Questions about Pharmaceutical X-Ray Systems
Below are answers to common questions from pharmaceutical plant owners when selecting an X-Ray inspection system.
Can a pharmaceutical X-Ray system detect all types of foreign objects?
No. Pharmaceutical X-Ray systems detect foreign objects based on density differences compared to the product. Metal (iron, steel, aluminum) and non-metal (glass, stone, rubber, hard plastic) foreign objects can be detected if the density difference is large enough. However, foreign objects with similar density to the product (e.g., compressed powder clumps) are difficult to detect. Dual-energy technology (Mettler Toledo X37, Anritsu KD74, Sesotec Raycon D) improves discrimination capability.
What is the annual maintenance cost for a pharmaceutical X-Ray system?
Annual maintenance costs range from 8,000-15,000 USD depending on the model and service package. For the Mettler Toledo X37, the standard maintenance package in Vietnam is approximately 10,000-12,000 USD/year, including X-ray tube inspection, sensor calibration, and replacement of wear parts (conveyor belt, motor). The Loma X5 has lower maintenance costs (~8,000-10,000 USD/year). The Sesotec Raycon D has the highest cost (~15,000 USD/year) due to importing parts from Germany.
Do pharmaceutical X-Ray systems comply with GMP Annex 1 standards?
Yes. All 5 systems in this article comply with GMP Annex 1 (sterile pharmaceutical production) when installed with the correct configuration. The Mettler Toledo X37 and Sesotec Raycon D offer optional IP65 enclosed conveyors, suitable for cleanroom areas of grade B and C. The Eagle Pack 400, Anritsu KD74, and Loma X5 only achieve IP54, requiring additional protective enclosures if installed in sterile areas.
What is the delivery and installation time for X-Ray systems in Vietnam?
Delivery time depends on the model and stock availability. For the Mettler Toledo X37, average delivery time is 4-6 weeks (newly manufactured at the Mettler Toledo UK factory), with installation and training taking 5-7 working days. The Eagle Pack 400 and Loma X5 have shorter delivery times (3-5 weeks) due to batch production. The Anritsu KD74 and Sesotec Raycon D have longer times (6-8 weeks) due to shipping from Japan/Germany.
How can I test the actual sensitivity of an X-Ray system before purchasing?
You can request the supplier to perform a test with your actual factory product samples. For the Mettler Toledo X37, Việt Đức Trí Group offers free testing at the HCMC showroom or by sending samples to the lab. The test includes: running product samples containing standard foreign objects (0.3 mm steel ball, 0.5 mm glass bead) through the system, recording detection rate and false reject rate.